This page contains recent updates to Municipal Codes that Rescom has been made aware of. Posted 5/30/2005 |
| New and revised return air requirement for City of Houston |
| This was revised by Richard Vrana to include the required free area for those who want to use square duct or the cavity of a building for return air chase |
| The duct sizing is based on nominal size of the duct |
| Have confirmed sizing for return air ductwork per IRC as follows: 6 square inches for each 1000 Btu nominal cooling output rating. |
| Tonnage |
Duct Size |
Duct Size Sq.In. |
Required Sq.In. |
| 1 |
10" |
78.5" |
72.0" |
| 1.5 |
12" |
113.4" |
108.0" |
| 2 |
14" |
153.86" |
144.0" |
| 2.5 |
16" |
200.96" |
180.0" |
| 3.0 |
18" |
254.34" |
216.0" |
| 3.5 |
18" |
254.34" |
240.0" |
| 4.0 |
20" |
314.0" |
242.40" |
| 5.0 |
2 - 16" |
380.0" |
360.0" |